Close [Control Panel].
7. Click the [Start] button on the task bar of Windows 95 and then click [Shut down...].
Select "Shut down the computer?" and click [Yes] button.
When the following message is displayed on the screen, remove floppy disk from the
floppy drive and press Ctrl+Alt+Delete keys simultaneously to restart the System.
It's now safe to turn off your computer
E. Calibration of touch panel
E. Calibration of touch panelE. Calibration of touch panel
E. Calibration of touch panel
1. When Windows 95 restarts, insert 1st "Open CNC Drivers Disk" into the floppy drive.
2. Invoke [Explorer] and click the left + mark of "3 1/2 Floppy(A:)" at [All Folders] and click
the left + mark of “Touch” folder. Click “Win95” folder that will appear succeedingly.
3. Execute Calwinf.exe
Calwinf.exeCalwinf.exe
Calwinf.exe by double-clicking its file name at [Contents of:'Win95']. Calibration
screen will appear. (The cross hairs in red is displayed on the upper-left corner of the
screen.)
4. Touch the center of the cross hairs with touch-pen. After touching, next cross hairs will
appear.
5. Repeat this procedure for 9 times. And then press [Enter] key.
6. Again press [Enter] key to finish this calibration.
7. Copy Calwinf.exe
Calwinf.exeCalwinf.exe
Calwinf.exe file to the proper folder(Example. C:\MMC) in the hard disk.