Edit Date Desig. Description
Title
Draw. No.
FANUC Open CNC
Setup procedure for Windows95/NT4.0
A-63707E
FANUC LTD
Sheet
8/12
Cust.
01 980908 Kayano New registration
04
000217
Kayano
ll pages modified
7. Remove the floppy disk from the floppy drive. When the following message is displayed
on the screen, click [Yes] button.
“Do you want to restart your computer now?”
C.
C.C.
C. Calibration of touch panel
Calibration of touch panelCalibration of touch panel
Calibration of touch panel
1. When Windows NT comes up, logon as the Administrator. Insert the first “Open CNC
Drivers Disk” into the floppy drive.
2. Open [Windows NT Explorer].
Click the [Start] button and point to [Programs]. Then click [Windows NT Explorer].
3. Click “3 1/2 Floppy (A:)” at [All Folders] and double-click “Touch” folder at
[Contents of ‘3 1/2 Floppy (A:)’]. Double-click “Nt40” folder at [Contents of ‘Touch’].
4. Execute Calwinfe
CalwinfeCalwinfe
Calwinfe(Calwinfe.exe) by double-clicking its file name at [Contents of ‘Nt40’].
Calibration screen will appear. (The cross hairs in red is displayed on the upper-left corner
of the screen.)
5. Touch the center of the cross hairs with touch-pen. After touching, next cross hairs will
appear. Repeat touching 9 times.
6. After touching all 9 cross hairs, press [Enter] key.
7. Again press [Enter] key to finish this calibration.
8. Click “(C:)” at [All Folders] on [Windows NT Explorer]. Then point to [File] menu and
select [New] and click [Folder]. “New Folder” will come up. Enter “MMC” from full
keyboard, then press [Enter] key.
9. Copy Calwinfe
CalwinfeCalwinfe
Calwinfe(Calwinfe.exe) from “\Touch\Nt40” folder of [3 1/2 Floppy (A:)] into
“C:\MMC” folder.
D.
D.D.
D. High Speed Serial Bus(HSSB) driver installation
High Speed Serial Bus(HSSB) driver installationHigh Speed Serial Bus(HSSB) driver installation
High Speed Serial Bus(HSSB) driver installation
PC-integrated i-Series and Intelligent Terminal Type 2 (hereafter, “Device”) have High
Speed Serial Bus (HSSB) Type 2 interface in them.
The Device without ISA extension unit uses I/O port address 280H - 28FH as HSSB
interface. This I/O address cannot be changed.
In case of the Device with ISA extension unit, you can select the I/O port addresses by the
rotary switches. In case of HSSB multi-connection, determine the I/O port addresses so as
not to conflict with the other HSSB interface boards and the other computer resources,
before doing the following steps.
Each Device which has HSSB interface is given “Node” number and distinguished by node
number at Windows. This is true for the Device which has only one HSSB interface (its node
number equals to 0).
1. Logon to Windows NT as the Administrator.
2. Close all application programs. You must close the [Control Panel] if it is running.
3. Open [Windows NT Explorer].