B-66244EN/03 2.FANUC PICTURE (Windows)
- 33 -
The signal display is used :
Check this check box to use the function for Signal display.
Change Signal Area:
Specify the type of the PMC address of the change signal which
displays pop-up window to display signal.
Change Signal Address:
Specify the address type of the change signal.
Change Signal Bit:
Specify the bit position of the change signal above by using a
number 0 to 7.
The operation is invalidated :
When the function that the action of the button control is not
executed is used, the check box is checked.
Change Signal Area:
Specify the type of the PMC address of the change signal not to
execute action of button control.
Change Signal Address:
Specify the address type of the change signal not to execute action
of button control.
Change Signal Bit:
Specify the bit position of the change signal above by using a
number 0 to 7.
The operation ratio change function displaying the custom screen is
used.:
If the RS232C-based ladder online monitor function and external
device I/O control are used when a custom screen created with
FANUC PICTURE is displayed, these operations abruptly slow
down. This is because the same task is used for screen display and
the CNC functions mentioned above, so processing time allocated
per unit time is reduced, thus increasing the time required to
complete processing.
With FANUC PICTURE, the ratio of (custom screen
operation:CNC function operation) = (80%:20%) is used by
default.
The operation ratio change function enables the operation ratio to
be dynamically changed by a PMC ladder according to the status
of the CNC.
Check this box to use this function. When this box is checked, the
dark display of the following input items disappears:
Interface area for operation ratio change
Signal Area, Signal Address:
Specify a one-byte PMC area signal used under the following
configuration for the interface signal area for operation ratio
change: