2.FANUC PICTURE (Windows) B-66244EN/03
- 76 -
(3) Interlocking-style indication
The button style indication during input of the interlock signal
helps the operator visually check the state of the button by
displaying the style that indicates the interlocking state. Since
both the interlocking style and on/off style are included, this style
requires more memory.
This interlocking style is specified in [Property] on the [Interlock
Image] tag.
There are several state indication check boxes for confirming the style
indication on the form. When all of these boxes are checked, the style
indications are prioritized as shown below. To confirm a lower-priority
style indication, uncheck the check box for a higher-priority style
indication.
Embedded-plug-style indication or embedded-plug-style indication by
an invalid signal
> Interlocking-style indication
> On/off-style indication
Property Pages
- General
Object ID:
Object ID managed in the form. This ID is automatically
assigned. The user cannot change this ID.
X, Y:
Set the coordinates of the upper-left corner of the screen switch
control.
Width, Height:
Set the width and height of the screen switch control.