FANUC Series 30i/31i/32i -MODEL A
Tool management function
magazine property/pot property
13507 Number of data items in the eighth magazine
NOTE
When this parameter is set, the power must be turned
off before operation is continued.
[Input type] Parameter input
[Data type] Word type
[Valid data range] 1 to 64(Extended to 240 or 1000 by the addition of an option)
This parameter sets the number of data items used with the eighth magazine.
13508 Start pot number of the eighth magazine
NOTE
When this parameter is set, the power must be turned
off before operation is continued.
[Input type] Parameter input
[Data type] Word type
[Valid data range] 1 to 9999
This parameter sets the start pot number to be used with the eighth magazine.
Pot numbers starting with the value set in this parameter and sequentially
incremented by 1 are assigned to all data items.