B-63945EN/02 9.DIGITAL SERVO
- 523 -
<2> Axis setting screen
On the axis setting screen, the following items can be specified:
• M1 (connector number for separate detector interface uni 1)
M2 (connector number for separate detector interface uni 2)
M3 (connector number for separate detector interface uni 3)
M4 (connector number for separate detector interface uni 4)
For an axis on which to use each separate detector interface
unit, enter a connector number with a number 1 to 8
(maximum number of connectors on a separate detector
interface unit).
When a separate detector interface unit is not connected and
a number that falls outside the valid range is entered, the
warning message “ILLEGAL DATA” is displayed. When
a separate detector interface unit is connected and a number
that falls outside the valid range is entered, the warning
message “DATA IS OUT OF RANGE” is displayed.
• 1-DSF
If the number of servo HRV3 and HRV4 controlled axes
that can be controlled by one DSP is limited, set the number
of axes controllable by one DSP.
Number of servo HRV3 controlled axes Setting: 3
Number of servo HRV4 controlled axes Setting: 1
The same value is set for axes other than Cs contour
controlled axes.
If a value other than 0, 1, and 3 is input, the warning
"INVALID FORMAT" is output.
• Cs (Cs contour controlled axis)
Enter spindle number (1 to 8) for the Cs contour controlled
axis. If a number other than 0 to 8 is entered, the warning
message “DATA IS OUT OF RANGE” is displayed.