11.TROUBLESHOOTING B-63945EN/02
- 628 -
11.25.10 System Alarms 114 to 130 (Alarms on the FSSB)
Causes
An alarm was detected on the FSSB.
NOTE
”/LINEx” following a message if displayed indicates
the number of an optical connector on an axis
control card.
LINE1 : COP10A-1 on the servo card
LINE2 : COP10A-2 on the servo card
LINE3 : COP10A-3 on the additional axis board
SYS_ALM114 FSSB DISCONNECTION
(MAIN -> AMP1) /LINEx
SYS_ALM115 FSSB DISCONNECTION
(MAIN -> PULSE MODULE1) /LINEx
SYS_ALM116 FSSB DISCONNECTION
(AMPn -> AMPm) /LINEx
SYS_ALM117 FSSB DISCONNECTION
(AMPn -> PULSE MODULEm) /LINEx
SYS_ALM118 FSSB DISCONNECTION
(PULSE MODULEn -> AMPm) /LINEx
SYS_ALM119 FSSB DISCONNECTION
(PULSE MODULE1 -> PULSE MODULE2) /LINEx
SYS_ALM120 FSSB DISCONNECTION
(MAIN <- AMP1) /LINEx
SYS_ALM121 FSSB DISCONNECTION
(MAIN <- PULSE MODULE1) /LINEx
SYS_ALM122 FSSB DISCONNECTION
(AMPn <- AMPm) /LINEx
SYS_ALM123 FSSB DISCONNECTION
(AMPn <- PULSE MODULEm) /LINEx
SYS_ALM124 FSSB DISCONNECTION
(PULSE MODULEn <- AMPm) /LINEx
SYS_ALM125 FSSB DISCONNECTION
(PULSE MODULE1 <- PULSE MODULE2) /LINEx
114: Communication between the axis control card and 1st
servo amplifier failed.
115: Communication between the axis control card and 1st
separate detector interface unit failed.
116: Communication between the nth and mth servo
amplifiers failed.
117: Communication between the nth servo amplifier and
mth separate detector interface unit failed.
118: Communication between the nth separate detector
interface unit and mth servo amplifier failed.
119: Communication between the 1st and 2nd separate
detector interface units failed.
120: Communication between the axis control card and 1st
servo amplifier failed.
121: Communication between the axis control card and 1st
separate detector interface unit failed.
122: Communication between the nth and mth servo
amplifiers failed.
123: Communication between the nth servo amplifier and
mth separate detector interface unit failed.
124: Communication between the nth separate detector
interface unit and mth servo amplifier failed.
125: Communication between the 1st and 2nd separate
detector interface units failed.
Replace the optical cable for the relevant connection. If the
error still occurs after replacement, replace the relevant axis
control card, servo amplifier(s), and/or separate detector
interface unit(s).
When the arrow points to the left, a power fault may occur in
the servo amplifier or separate detector interface unit at the
base of the arrow. Check the +24 V power supply input to
the relevant unit and the +5 V power supply for the pulse
coder output from the relevant unit for an error such as a
ground fault.