B-63945EN/02 9.DIGITAL SERVO
- 537 -
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
1005 DLZx
#1 DLZx 0 : The normal method (dog) is used for reference position return.
1 : Reference position setting without dogs is used (axis by axis).
NOTE
A reference position can be set axis by axis by
setting parameter DLZx. Reference position setting
without dogs cannot be used for a spindle
positioning axis and Cs contour axis. When these
axes are involved, use parameter DLZx.
#7 #6 #5 #4 #3 #2 #1 #0
1006 ZMIx
#5 ZMIx 0: Reference position return and backlash initial direction is +.
1: Reference position return and backlash initial direction is -.
* After ZRN signal becomes 1, manual feed direction is always the
direction set by this parameter irrespective of an axis selection
signal.