B-63945EN/01 1.DISPLAY AND OPERATION
- 57 -
1.6.3 Tracing Data
Starting tracing
1 Display the waveform diagnosis graph screen.
2 Press the [TRACE] soft key to start tracing.
"Now Sampling…" appears in the upper part of the screen. When
tracing ends, the indication "Now Sampling…" disappears.
Even when the screen display is changed to another screen, tracing
continues.
Canceling tracing
When the [CANCEL] soft key is pressed during tracing, tracing stops.
Moving, extending, and reducing a waveform
When [H-DOBL] or [H-HALF] is pressed, the length of the time axis
on one screen is extended or reduced, respectively.
When a waveform cannot fit in one screen, the time axis can be
moved by pressing [←TIME] or [TIME→].
Furthermore, pressing [CH-1], [CH-2], [CH-3], or [CH-4], a submenu
appears.