B-63945EN/02 APPENDIX A.ALARM LIST
- 659 -
Number Message Description
1593 EGB PARAMETER SETTING ERROR Error in setting a parameter related to the EGB
(1) The setting of SYN, bit 0 of parameter No. 2011, is not
correct.
(2) The slave axis specified with G81 is not set as a rotation
axis. (ROT, bit 0 of parameter No. 1006)
(3) Number of pulses per rotation (Parameter (No. 7772 or No.
7773) or (No. 7782 or 7783) is not set.)
(4) For a hobbing-machine-compatible command, parameter No.
7710 is not specified.
1594 EGB FORMAT ERROR Error in the format of the block of an EGB command
(1) T (number of teeth) is not specified in the G81 block.
(2) In the G81 block, the data specified for one of T, L, P, and Q
is out of its valid range.
(3) n the G81 block, only one of P and Q is specified.
(4) In the G81.5 block, there is no command for the master or
slave axis.
(5) In the G81.5 block, data out of the specified range is
specified for the master or slave axis.
1595 ILL-COMMAND IN EGB MODE During synchronization with the EGB, a command that must not
be issued is issued.
(1) Slave axis command using G27, G28, G29, G30,G30.1,
G33, G53, etc.
(2) Inch/metric conversion command using G20, G21, etc.
1596 EGB OVERFLOW An overflow occurred in the calculation of the synchronization
coefficient.
1597 EGB AUTO PHASE FORMAT ERROR Format error in the G80 or G81 block in EGB automatic phase
synchronization
(1) R is outside the permissible range.
1598 EGB AUTO PHASE PARAMETER
SETTING ERROR
Error in the setting of a parameter related to EGB automatic
phase synchronization
(1) The acceleration/deceleration parameter is not correct.
(2) The automatic phase synchronization parameter is not
correct.
1805 ILLEGAL COMMAND [I/O Device]
An attempt was made to specify an illegal command during I/O
processing on an I/O device.
[G30 Zero Return]
The P address Nos. for instructing No. 2 to No. 4 zero return
are each out of the range 2 to 4.
[Single Rotation Dwell]
The specified spindle rotation is “0” when single rotation dwell
is specified.
[Three–dimensional Tool Offset]
A G code that cannot be specified was specified in the
three–dimensional tool offset mode.
Scaling instruction G51, skip cutting G31 and automatic tool
length measurement G37 were specified.
1806 DEVICE TYPE MISS MATCH An operation not possible on the I/O device that is currently
selected in the setting was specified.
This alarm is also generated when file rewind is instructed even