Draw.
Title
Aochi 05.10.05 01
PAGE
FANUC SYNCHRONOUS BUILT-IN SERVO
MOTOR D
iS series Parameter Description
13/13
FANUC LTD.
B-65332EN/01-01
Descri
tionDesi
n Date Edit
.
Tojyo
5.Detection of an overheat alarm
There are the following methods for the detection of the overheat alarm.
(1) Detect the signal of thermostat via PMC ladder and
Please refer to the following descriptions.
FANUC SYNCHRONOUS BUILT-IN SERVO MOTOR D
iS series Descriptions(B-65332EN)
III. HANDLING, DESIGN, AND ASSEMBLING 2.2 THERMOSTAT CONNECTION
(2) Detect an overheat alarm by servo software.
As for the software version, please refer to the following technical report
TMS05/038 B-65270JA/05-002
#7 #6 #5 #4 #3 #2 #1 #0
2713(FS15i)
CKLNOH
2300(FS30i,16i)
CKLNOH(#7) Thermostat signal is:
1: Monitored by servo software.
0: Not monitored by servo software.
CAUTION
This function bit is included in the motor standard parameters. It is set
automatically when servo parameter initialization is performed with a
motor ID number set.
In the CNC that cannot use interface G326 of the PMC, if this function
bit is set to 1, a servo alarm (motor overheat) is issued. If this occurs,
set the function bit to 0.
* For the FS15i, set bit 7 of parameter No. 2713 to 0; for the Power
Mate i, set bit 7 of parameter No. 2300 to 0.