2.SPECIFICATIONS SPECIFICATIONS B-65332EN/01
- 8 -
2.2 SPECIFICATION LIST
*1
Model
Items Unit
D3000/150is D2100/150is D1500/200is D1200/250is
Spec.No.
-
A06B-0487-B400
A06B-0487-B402
A06B-0487-B300
A06B-0487-B302
A06B-0486-B300
A06B-0486-B302
A06B-0485-B500
A06B-0485-B502
Cooling condition *
2
-
LC NC LC NC LC NC LC NC
Max. speed min
-1
150
(75)
150
(75)
200
(100)
250
(125)
Upper speed for the
max. torque
min
-1
100
(50)
100
(50)
200
(90)
200
(100)
Max.
3000
2700)
(
2100
(1900)
1500
(1500)
1200
(1200)
Rated
torque
*
3
Cont. *
4
Nm
1200
(1000
) (500)
600 840
(750)
420
(375)
600
(600)
300
(300)
480
(480)
240
(240)
Max.
31.4
(14.1)
22.0
(10.0)
31.5
(14.2)
25.2
(12.6)
Rated
output
*
3
Cont. *
4
kW
18.8
(7.9)
9.4
(4.0)
13.2
(5.9)
6.6
(3.0)
12.7
(6.3)
6.4
(3.2)
12.6
(6.3)
6.3
(3.2)
Max.
127
(113)
127
(113)
114
(114)
88.4
(88.4)
Rated
current
*
3
Cont. *
4
Arms
51
(45)
25
(22)
51
(45)
25
(22)
46
(46)
23
(23)
35.4
(35.4)
17.7
(17.7)
Max.current of
amplifier
Ap
180
(160)
180
(160)
180
(160)
180
(160)
Torque constant
Nm/Arms
2 3.6 1 6.5 1 3.2 1 3.5
Number of poles P ole 88 88 75 56
Resistance U-V
Ω
0.98±5% 0.75±5% 0.76±5% 1.81±5%
Thermal time constant
min. 1 60 1 60 1 60 1 60
ICcode *
5
-
9 W7A7 0A8 9W7A7 0A 8 9W7A7 0A 8 9W7A7 0A8
Cooling cap
4
acity * W 3830
-
2930
-
2340
-
2130
-
Stator 74 59 44 37
Weight
Rotor
kg
37 29 18 19.3
Rotor inertia kgm
2
1.70 1.28 0.49 0.26
Amplifier (SVM)
-
SVM1-180HVi
(SVM1-160i)
SVM1-180HVi
(SVM1-160i)
SVM1-180HVi
(SVM1-160i)
SVM1-180HVi
(SVM1-160i)
for PSMselection
Max./Cont. *
6
kW
39.4/20.1
(20.4/8.9)
28.1/14.2
(14.8/6.7)
36.4/13.5
(19.1/7.1)
50.3/12.6
(25.2/6.3)
* Standard values at an ambient temperature of 25°C and a power supply voltage of 400 V. Values in ( ) are for 200V.
The values may vary depending on the ambient temperature, digital servo software, parameters, power supply voltage, amplifier specifications,
1
and others.
*2 “LC” means “Liquid Cooling”. “NC” means “No Cooling”. If liquid is not water but oil, continuous torque will be reduced depending on the
characteristics of coolant.
teristics of machine.
*3 Varies depending on the actual cooling conditions and the thermal charac
aranteed when the cooling condition is satisfied.
*4 Continuous data are gu
*5 Based on EN60034-6.
6 Reference data for PSM selection. Not guaranteed data. Add this raw value when PSM selection.
*