2.SELECTION METHODS CONFIGURATIONS AND SELECTION B-65332EN/01
2.1.3 Maximum load inertia
- 42 -
Maximum load inertia is limited from momentum energy of axis and
the capacity of servo amplifier.
Moving condition should not exceed the limitation shown below.
Model name
Power source
voltage [V]
Maximum speed
[min
-1
]
Maximum load
inertia [kgm
2
] *
D3000/150is 400 150 202.5
D2100/150is 400 150 202.9
D1500/200is 400 200 114.4
D1200/250is 400 250 73.2
D370/300is 400 300 7.8
D260/600is 400 600 12.7
D260/300is 400 300 7.8
D110/300is 400 300 7.8
D85/400is 400 400 4.1
D3000/150is 200 75 387.3
D2100/150is 200 75 387.7
D1500/200is 200 100 218.4
D1200/250is 200 125 139.8
D370/300is 200 150 60.7
D260/600is 200 300 24.2
D260/300is 200 150 60.7
D110/300is 200 150 60.7
D85/400is 200 200 20.5
* without rotor inertia
NOTE
This table based on the driving condition using a
specified amplifier. To get other information, such as
lower speed, larger inertia, larger amplifier and so on,
contact FANUC in advance.