B-65332EN/01 SPECIFICATIONS 2.SPECIFICATIONS
- 9 -
*1
Model
D370/300is D260/600is D260/300is D110/300is
Unit Items
A06B-0484-B400
A06B-0484-B402
A06B-0484-B310
A06B-0484-B312
A06B-0484-B300
A06B-0484-B302
A06B-0484-B100
A06B-0484-B102
-
Spec. No
LC NC LC NC LC NC LC NC
-
Cooling condition *
2
300
(150)
600
(300)
300
(150)
300
(150)
min
-1
Max. speed
200
(100)
400
(200)
200
(100)
200
(100)
min
-1
Upper speed for the
max. torque
370
(370)
260
(260)
260
(260)
110
(110)
Max.
150
(150)
75
(75)
105
(105)
55
(55)
105
(105)
55
(55)
45
(45)
25
(25)
Nm
Cont. *
4
Rated
torque
*
3
7.8
(3.9)
11.0
(5.5)
5.5
(2.8)
2.3
(1.2)
Max.
4.8
(2.4)
2.4
(1.2)
6.6
(3.3)
3.3
(1.6)
3.3
(1.6)
1.7
(0.8)
1.4
(0.7)
0.7
(0.4)
kW
Cont. *
4
Rated
output
*
3
56.6
(56.6)
83.2
(83.2)
56.6
(56.6)
56.6
(56.6)
Max.
22.6
(22.6)
11.3
(11.3)
33.3
(33.3)
16.7
(16.7)
22.6
(22.6)
11.3
(11.3)
22.6
(22.6)
11.3
(11.3)
Arms
Cont. *
4
Rated
current
*
3
80
(80)
180
(160)
80
(80)
80
(80)
Ap
Max. current of
amplifier
6.5 3.1 4.6 1.9
Nm/Arms
Torque constant
40 40 40 40 Pole Number of poles
2.1±5% 0.95±5% 1.6±5% 0.93±5%
Ω
U-V Resistance
1 60 1 60 1 60 1 60 min.
Thermal time constant
9W7A7 0A8 9W7A7 0A8 9W7A7 0A8 9W7A7 0A8
-
IC code *
5
1610
-
3220
-
720
-
720
-
W Cooling capacity
16 12.5 12.5 8 Stator
7 5.5 5.5 3
kg
Rotor
Weight
0.045 0.033 0.033 0.018 kgm
2
Rotor inertia
SVM1-80HVi
(SVM1-80i)
SVM1-180HVi
(SVM1-160i)
SVM1-80HVi
(SVM1-80i)
SVM1-80HVi
(SVM1-80i)
-
Amplifier (SVM)
11.2/5.4
(7.3/3.0)
18.8/8.4
(12.8/4.8)
8.1/3.9
(5.4/2.2)
3.8/1.7
(2.7/1.0)
kW
for PSM selection
Max./Cont. *
6
*1 Standard values at an ambient temperature of 25°C and a power supply voltage of 400 V. Values in ( ) are for 200V.
The values may vary depending on the ambient temperature, digital servo software, parameters, power supply voltage, amplifier specifications,
and others.
*2 “LC” means “Liquid Cooling”. “NC” means “No Cooling”. If liquid is not water but oil, continuous torque will be reduced depending on the
characteristics of coolant.
*3 Varies depending on the actual cooling conditions and the thermal characteristics of machine.
*4 Continuous data are guaranteed when the cooling condition is satisfied.
*5 Based on EN60034-6.
*6 Reference data for PSM selection. Not guaranteed data. Add this raw value when PSM selection.