5.4 Releasing of overlapping control
The overlapping control are released for the following besides the overlapping control selection signal
is turned off.
(1) Emergency stop
(2) Reset
(3) Servo alarm
(4) Servo off
(5) Over travel alarm
(6) Alarm concerning overlapping control
(7) P/S000 alarm
When this system enters into the state of either the above-mentioned while the overlapping control,
this system will automatically enter the feed hold state (in automatic operation) or the interlock state (in
manual operation).
5.5 State signal of axes during overlapping control
State signal During overlapping control
Movement state signal
MVn F0102
Signal of the master axis is usual.
Signal of the slave axis does not depend on the
overlapping pulse and reflect the movement by the
command on the slave side. (1)
Movement direction signal
MVDn F0106
Signal of the master axis is a direction of the movement of
the master axis.
Signal of the slave axis is a direction of the movement
after the overlapping pulse is added.
In-position signal
INPn F0104
Signal of the master axis is usual.
The slave axis reflects the state after the overlapping
pulse is added.
(1) In the check on position deviation, parameter No.1828 is used as a limit value if
movement pulse is commanded to the motor (regardless of the master or slave),
parameter No.1829 is used if any movement pulse is not commanded. It does not
depend on the state of this signal.