New registration
FANUC Series 16i/18i-TA/TB
One Path Overlapping control
on two paths system
A -
7644
CUST.
TITLE
DRAW.NO.
8191 Rapid traverse override F0 rate of each axis during overlapping control
Data format : words axis type
Data unit :
Data range :
Data range
Increment system Data unit
IS-A, IS-B IS-C
Metric system machine 1 mm/min 6 15000 6 12000
Inch system machine 0.1 inch/min 6 6000 6 4800
Rotary axis 1 deg/min 6 15000 6 12000
Rapid traverse override F0 rate of each axis(both master and slave axes) during
overlapping control is set.
8192
Liner type rapid traverse acceleration/deceleration time constant of each
axis during overlapping control
Data format : words axis type
Data unit :msec
Data range :0 4000
Liner type rapid traverse acceleration/deceleration time constant of each axis during
overlapping control (both the master and the slave axis) is set.
8193 Maximum feed rate during overlapping control
Data format : 2 words axis type
Data unit :
Data range :
Data range
Increment system Data unit
IS-A, IS-B IS-C
Metric system machine 1 mm/min 6 240000 6 100000
Inch system machine 0.1 inch/min 6 76000 6 48000
Rotary axis 1 deg/min 6 240000 6 100000
Maximum feed rate during overlapping control is set.