A -
7644
CUST.
TITLE
DRAW.NO.
4. Signals
#7 #6 #5 #4 #3 #2 #1 #0
G0190/G1190 OVLS8 OVLS7 OVLS6 OVLS5 OVLS4 OVLS3 OVLS2 OVLS1
Overlapping control selection signal (input)
To turn this signal to HIGH from LOW starts overlapping control of corresponding axis. The axis
set in parameter No.8186 is made the master axis. However, when a setting value of parameter
No.8186 of corresponding axis is 0, even if this signal is risen, the overlapping control will not be
performed. To turn this signal to LOW from HIGH during overlapping control releases
overlapping control of corresponding axis.
#7 #6 #5 #4 #3 #2 #1 #0
F0118/F1118 SYN80 SYN70 SYN60 SYN50 SYN40 SYN30 SYN20 SYN10
Overlapping control state signal (output)
This signal become HIGH when the corresponding axis is under overlapping control state. This
signal become LOW when the corresponding axis is not under overlapping control state. The
controlling state of overlapping is not always same as the signal state of overlapping control
selection signal(OVLSn). For example, it is not effective to rise OVLSn under alarm state.
Moreover, when the servo alarm is detected during overlapping control, overlapping control will
be automatically released. When overlapping control is performed, it is necessary to confirm the
state of this signal.(This signal is also output for the axes those are driven by synchronous
operation.