B-63943EN/02 7.SERVO INTERFACE
- 119 -
NOTE
1 As servo amplifier modules, αi series SVM
(supported by the 30i/31i/32i) or βi series SVM
units must be used.
2 The number of axes that can be controlled varies
also depending on the software series, the servo
card, and the type of an additional axis board.
3 When the number of axes that was set for the first
FSSB line is zero, no axes can be set for the
second FSSB line.
4 Unused optical connectors must be covered with
the caps.
<Cable types>
Cable drawing number Usage
A02B-0236-K851 to K856
(A66L-6001-0023#~)
For internal
connection
Length of 10 m or less
A66L-6001-0026#~ For external
connection