PROGRAMMING
3. HIGH–SPEED RESPONSE
FUNCTION
B–63174EN/02
PROGRAMMING
(Power Mate i–H only)
236
CAUTION
After modifying the following parameters, be sure to perform
compilation:
S Parameter No. 1011 (number of controlled axes)
S Parameter No. 1020 (program axis name of each axis)
A desired compiled motion program can be executed by pressing the start
button corresponding to the program number.
NOTE
1 A motion program is executed, starting with the first block at
all times.
2 When compared with a block specifying an incremental
command, a block specifying an absolute command may
require a longer time before the start of execution. So,
create a program using incremental commands wherever
possible. Moreover, automatic reference position return
operation (G28) may also require a longer time before the
start of execution.
3 Motion programs as many as the number of controlled axes
can be executed simultaneously. However, multiple motion
programs, each specifying the same axis or the same M
codes, cannot be executed simultaneously.
4 While the reset signal RST is on, motion programs cannot
be executed.
CAUTION
If an absolute command is specified during servo–off or
torque limit control, positioning at the specified position may
be impossible.
CAUTION
When the motion program alarm signal HALMn/HALMMn is
turned on, the motion program stops with an alarm. (Even
when the alarm signal AL is turned on, the motion program
does not stop with an alarm if the motion program alarm
signal HALMn/HALMMn is off.)
a. Be sure to set the following parameters to 0:
Bit 0 (INM) of parameter No. 1001
Bit 0 (ISA) of parameter No. 1004
Bit 7 (IPR) of parameter No. 1004
NOTE
If these parameters are not set to 0, the mode cannot be
switched to the high–speed response mode.
Motion program
execution
Notes on parameters