OPERATION
B–63174EN/02
11. SETTING AND DISPLAYING DATA
475
With this function, functions of the switches on the machine operator’s
panel can be controlled from the CRT/MDI panel.
Jog feed can be performed using numeric keys.
Not to display the software operator’s panel, set the bits 7 (NS0) and 6
(NS2) of parameter No. 7202 to 1.
Displaying and Setting the Software Operator’s Panel
1 Press function key
OFFSET
SETTING
.
2 Press the continuous menu key
, then press chapter selection soft
key [OPR].
3 The screen consists of several pages.
Press page key
PAGE
or
PAGE
until the desired screen is displayed.
OPERATOR’S PANEL O0000 N00000
MODE : MDI AUTO EDIT STEP JOG ZRN
HNDL FEED : DISABLE HX HY HZ
H/S MULTI. : ***(HNDL: *1 STEP: *1)
RAPID OVRD. : 100% 50% 25% F0
JOG FEED : 2.0%
**************
FEED OVRD. : 100%
***
ACTUAL POSITION (ABSOLUTE)
X 0.000 Y 0.000
Z 0.000
>_
MDI **** *** *** 16:05:59
[][][][][]MACRO MENU OPR (OPRT)
OPERATOR’S PANEL O0000 N00000
BLOCK SKIP : OFF J ON
SINGLE BLOCK : J OFF ON
MACHINE LOCK : OFF J ON
DRY RUN : J OFF ON
PROTECT KEY : J PROTECT RELEASE
FEED HOLD : J OFF
ACTUAL POSITION (ABSOLUTE)
X 0.000 Y 0.000
Z 0.000
S 0 T0000
MDI **** *** *** 16:05:59
[][][][][]MACRO MENU OPR (OPRT)
11.4.7
Displaying and Setting
the Software
Operator's Panel
OPR
Continuous menu key