3)
• Data restore at program check mode end
In case that the parameter PGR (No.3454#3) is set to “1”, the data, which are
changed during the program check mode, are restored to the data at the program
check mode start when ending the program check mode.
By this, after ending the program check mode, the automatic operation can be
executed with the data before the program check mode start.
The data to be restored are the same as those of described on “Data save at program
check mode start”.
Note
1. The absolute coordinate and relative coordinate of the axis, whose
the control axis select signal (PMC axis control) EAX* <G0136> is
“1” at the program check mode end, are not restored.
2. The data of the periodic maintenance screen are not restored.
3. When the parameter PGS (No.3001#6) is set to “1”, the M, S, T, and
B codes are not restored.
5)
• Dynamic graphic display
When the parameter PGR (No.3454#3) is set to “1”, the data, which are described on
“Data save at program check mode start”, are saved at the start of the path graphic or
solid graphic drawing of the dynamic graphic display.
Additionally, the data, which are changed during drawing, are restored to the data at
the drawing start when ending the path graphic or solid graphic drawing.
By this, after ending the path graphic or solid graphic drawing, the automatic operation
can be executed with the data before the path graphic or solid graphic drawing start.
4)
Edit
Apprv.
Desig.
Sheet
TITLE
Draw
No.
Date
Design
Descri
tion
Date
FANUC Series 16i/18i/21i–MB, 18i–MB5
Program check function Specifications
A-79461E
02
2004.3.29
Addition of 2)
2004.2.29
7
15
03
2004.6.25
Addition of 3)
04
2004.6.30
Addition of 4)
05
2004.7.26
Addition of 5)