OPERATION
7. ALARM AND SELF–DIAGNOSIS
FUNCTIONS
B–63604EN/01
488
Up to 25 of the most recent CNC alarms are stored and displayed on the
screen.
Display the alarm history as follows:
Procedure for Alarm History Display
1 Press the function key
MESSAGE
.
2 Press the chapter selection soft key
[HISTRY].
The alarm history appears.
The following information items are displayed.
(1)The date the alarm was issued
(2)Alarm No.
(3)Alarm message (some contains no message)
(4)Page number
3 Change the page by page key
PAGE
or
PAGE
.
4 To delete the recorded information, press the softkey
[(OPRT)]
then the [DELETE] key.
ALARM HISTORY O0100 N00001
MEM
* * * *
* * * * * *
19 : 47 : 45
(1)97.01.14 16:43:48
(2)010 (3)MPROPER G–CODE
97.01.13 8:22:21
506 OVER TRAVEL : +X
97.01.12 20:15:43
417 SERVO ALARM : X AXIS DGTL PARAM
ALARM
MSG
HISTRY
(OPRT)
PAGE=1
(4)
7.2
ALARM HISTORY
DISPLAY