APPENDIX
B–63604EN/01
G. ALARM LIST
739
Number ContentsMessage
453 n AXIS : SPC SOFT DISCONNECT
ALARM
Software disconnection alarm of the α pulse coder.
Turn off the power to the CNC, then remove and insert the pulse cod-
er cable. If this alarm is issued again, replace the pulse coder.
456 n AXIS : ILLEGAL CURRENT LOOP An illegal current control period was specified.
The amplifier pulse module in use does not match high–speed HRV. Al-
ternatively, the system does not satisfy a constraint for performing high–
speed HRV control.
457 n AXIS : ILLEGAL HI HRV (250US) It is specified that, when the current control period is 250 ms, high–
speed HRV control is to be used.
458 n AXIS : CURRENT LOOP ERROR The specified current control period dose not match the actual current
control period.
459 n AXIS : HI HRV SETTING ERROR In a pair of axes in which one axis has an odd servo axis number (param-
eter No. 1023) and the other has an even servo axis number that is adja-
cent to the odd servo axis number, high–speed HRV control is sup-
ported for one of the axes and not supported for the other axis.
460 n AXIS : FSSB DISCONNECT FSSB communication was disconnected suddenly. The possible
causes are as follows:
1) The FSSB communication cable was disconnected or broken.
2) The power to the amplifier was turned off suddenly.
3) A low–voltage alarm was issued by the amplifier.
461 n AXIS : ILLEGAL AMP INTERFACE The axes of the 2–axis amplifier were assigned to the fast type interface.
462 n AXIS : SEND CNC DATA FAILED Because of an FSSB communication error, a slave could not receive
correct data.
463 n AXIS : SEND SLAVE DATA
FAILED
Because of an FSSB communication error, the servo system could not
receive correct data.
464 n AXIS : WRITE ID DATA FAILED An attempt was made to write maintenance information on the amplifier
maintenance screen, but it failed.
465 n AXIS : READ ID DATA FAILED At power–up, amplifier initial ID information could not be read.
466 n AXIS : MOTOR/AMP
COMBINATION
The maximum current rating for the amplifier does not match that for the
motor.
467 n AXIS : ILLEGAL SETTING OF
AXIS
The servo function for the following has not been enabled when an axis
occupying a single DSP (corresponding to two ordinary axes) is speci-
fied on the axis setting screen.
1. Learning control (bit 5 of parameter No. 2008 = 1)
2. High–speed current loop (bit 0 of parameter No. 2004 = 1)
3. High–speed interface axis (bit 4 of parameter No. 2005 = 1)
468 n AXIS : HI HRV SETTING ERROR
(AMP)
This alarm is issued if it is specified that high–speed HRV control is to
be used for a controlled axis connected to an amplifier for which high–
speed HRV control cannot be used.
The details of servo alarm are displayed in the diagnosis display (No. 200
and No.204) as shown below.
#7
OVL200
#6
LV
#5
OVC
#4
HCA
#3
HVA
#2
DCA
#1
FBA
#0
OFA
#7 (OVL) : An overload alarm is being generated.
#6 (LV) : A low voltage alarm is being generated in servo amp.
#5 (OVC) : A overcurrent alarm is being generated inside of digital servo.
#4 (HCA) : An abnormal current alarm is being generated in servo amp.
#3 (HVA) : An overvoltage alarm is being generated in servo amp.
#2 (DCA) : A regenerative discharge circuit alarm is being generated in servo amp.
D Details of servo alarm