GFK-1546 Chapter 2 FSSB Setting Screens 2 - 7
2
Settings
When the [(OPRT)] soft key is pressed on the Amplifier Setting or Axis Setting screen, the
following soft keys are displayed:
[SETING] [CANCEL] [INPUT ] [ ] [ ]
To set the parameters, move the cursor to each item in MDI mode or Emergency Stop condition,
enter a number, and press the [INPUT] soft key ( <INPUT> key on the MDI panel).
Then, press the [SETING] soft key. If a warning occurs, the values are incorrect and must be
corrected.
To display the values set in the parameters, press the [CANCEL] soft key.
When the CNC is powered ON, the values set in the parameters are displayed.
Note
Do not set the values for the parameters by MDI input or G10 input. The values
for these parameters can only be set on the FSSB Setting screens.
If a warning occurs when the [SETING] soft key is pressed, enter the correct
value or press the [CANCEL] soft key to stop the warning. Pressing the
<RESET> key will not release the warning.
Amplifier Setting Screen
The following item can be set on the Amplifier Setting screen:
Item Name Description
AXIS Axis Number
Enter the axis number from 1 to the maximum number of
controlled axes.
If a value that is out of the data range is entered, the warning
"FORMAT ERROR" occurs.
When the [SETING] soft key is pressed, if 0 or overlapped
numbers are set, the warning "DATA IS OUT OF RANGE"
occurs, and input numbers are not set in their parameters.