3 - 16 Alpha Series Servo Amplifier Unit (SVM) with FSSB - April 1998 GFK-1546
3
4. Enter the axis number on the Amplifier Setting screen.
AMPLIFIER SETTING
NO. AMP SERIES UNIT CUR. [AXIS] NAME
1 A1-L α SVM 40A [ 2 ] Y
2 A2-L α SVM 40A [ 1 ] X
3 A3-L α SVM 40A [ 4 ] A
4 A3-M α SVM 80A [ 3 ] Z
NO. EXTRA TYPE PCB ID
5 M1 A 0008 DETECTOR(4AXES)
>
MDI **** *** *** 13:11:56
[ AMP ] [ AXIS ] [MAINTE ] [ ] [(OPRT) ]
5. Press the [SETING] soft key.
6. Press the SYSTEM function key.
7. Press the > key several times to display the [FSSB] soft key. Then, press the
[FSSB] soft key to change the Amplifier Setting screen.
8. Press the [AXIS] soft key.
AXIS SETTING
AXIS NAME AMP M1 M2 1-DSP Cs TNDM
1 X A2-L 0 0 0 0 0
2 Y A1-L 0 0 0 0 0
3 Z A3-M 0 0 0 0 0
4 A A3-L 0 0 0 0 0
5 B — 1 0 0 0 0
>
MDI **** *** *** 13:11:56
[ AMP ] [ AXIS ] [MAINTE ] [ ] [(OPRT) ]
9. Press the [SETING] soft key. The setting will be complete after you turn the CNC OFF and
then ON.