GFK-1546 5 - 1
Chapter
Troubleshooting
Pulse Coder
Number of
NC
Alarms
Message Meaning
360 n axis : abnormal checksum (int) Checksum alarm occurred in the pulse coder (int).
361 n axis : abnormal phase data (int) Abnormal phase data alarm occurred in the pulse coder (int).
362 n axis : abnormal rev. data (int) Abnormal rev. data alarm occurred in the pulse coder (int).
363 n axis : abnormal clock (int) Clock alarm occurred in the pulse coder (int).
364 n axis : soft phase alarm (int) Internal pulse coder data is abnormal.
365 n axis : broken LED (int) Pulse coder LED is abnormal
366 n axis : pulse miss (int) Pulse miss alarm occurred in the pulse coder (int).
367 n axis : count miss (int) Count miss alarm occurred in the pulse coder (int).
368 n axis : serial data error (int) Serial data was not received from the internal pulse coder.
369 n axis : data transmission error (int) CRC error or stop bit error occurred in the pulse coder (int).
380 n axis : broken LED (ext) External pulse coder LED is abnormal.
381 n axis : abnormal phase (ext lin) Abnormal phase data alarm occurred in the external linear scale.
382 n axis : count miss (ext) Count miss alarm occurred in the external pulse coder.
383 n axis : pulse miss (ext) Pulse miss alarm occurred in the external pulse coder.
384 n axis : soft phase alarm (ext) External pulse coder data is abnormal.
385 n axis : serial data error (ext) Serial data was not received from the external pulse coder.
386 n axis : data transmission error (ext) External pulse coder data is CRC error or stop bit error
5