Connection of serial spindle and analog spindle
I
8
.
I
I
I
I
8
---e.-.---..----.....---.......
Spindle of ,
path2
Note 1
Note2
Note3
Note4
Note5
. Note6
JA41
JA40
MOTHER
- ’ ‘.. -.y.:.* * :.:...:.::t,:.:.:,:
,~~}_~
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
:.:.:.:.:.~:.f:,:.:.:,:.~.:.:.:.:.:.:.:,:
. . . . . . ..‘.+‘...‘...........‘..............
,
] Antog /sp3#1/
BOARD
Spindle of
path1
Spindle can be connected up to two axes in each path.
In FS18i system, spindle can be connected up to one axis in path2
Analog spindle can be connected up to one axis in only one path of path1 or path2
If analog spindle is connected, serial spindle2 can not be connected.
In FSlSi system, if analog spindle is connected in path2, serial spindle can not be
connected.
Connection of serial spindle is as follows,
Spindle1 and spindle2 of path1
: Same as spindle1 and spindle2 in one-path
control
Spindle1 and spindle2 of path2
: Same as spindle3 and spindle4 in one-path
control
The connector of analog spindle is always “JA40”. It is determined by parameter
EAS(No.3702#5) whether analog spinclle’is used in path1 or paths.
Position coder of analog spindle can not be used.