Title 9083 / 9087 / 90A3 / 90A7
Learning Control Operator’s Manual
03 '00.06.07 N.Sonoda Qualified 2'nd issue Draw No.
02 ‘99.01.14 K.Maeda Qualified 1’st issue
A - 63639E - 034
01 ‘97.12.08 K.Maeda Newly designed Sheet 015
Edit Date Design Description / 070
5.1.3 Setting servo parameters (In case semi-closed and 0.1µm :Serial pulse coder A, α1000 or α64)
According to the detail, refer to “AC SERVO MOTOR α series Parameter Manual”.
Because all servo parameters (No.2000 - No.2269) are axis type, you should set it for each axis.
(1) Set the following parameters fitted each motor and machine.
• No.2000#1 - #0 set to 01.
• No.2001#7 - #0 set to 00000000.
• No.2020 set to the Motor number.
• No.2021 set to Load Inertia ratio.
• No.2022 set to the motor rotation direction. ( 111 or –111)
• No.2023 set to 819.
• No.2024 set to 1250.
• No.2084 set to SDMR1.
• No.2085 set to SDMR2.
(Example 1) Lead pitch of ball screw is 12 mm/rev. (0.1 µm)
SDMR2
SDMR1
100
12
1000000
120000
→=
(Example 2) Rotary axis, 4/10000 deg detective unit and 900000 pulses/rev
SDMR2
SDMR1
100
90
1000000
900000
→=
(Example 3) Linear motor, LS486 and 0.1µm detective unit
()
SDMR2
SDMR1
128
50
20/20128
1.0/5
→=
×
(2) Turn off the power supply, then turn it on. (Auto loading)
(Note 1) In case of High-speed axis, set the following parameter, turn on and off the power supply.
• No.2005#4 set to 1 for High-speed axis.
♦ You don’t need this process in 90A7 series.
(Note 2) In case of Learning axis, set the following parameter, turn on and off the power supply.
• No.2008#5 set to 1 for Learning axis.
(Note 3) In case of Linear motor, set the following parameter, turn on and off the power supply.
• No.2010#2 set to 1.
• No.2023 set to 5000/10.
• No.2024 set to 160000/10.
• No.2112 set o 512∗(60/20)=1536.