Title 9083 / 9087 / 90A3 / 90A7
Learning Control Operator’s Manual
03 '00.06.07 N.Sonoda Qualified 2'nd issue Draw No.
02 ’99.01.14 K.Maeda Qualified 1’st issue
A - 63639E - 034
01 ’97.12.08 K.Maeda Newly designed Sheet 053
Edit Date Design Description / 070
9-5. Full-closed system
In series 16 or 18 (Model B or C), Servo axis module (A20B-2902-0061) for Learning control does not support
separate serial pulse coder. You should use the scale or encoder of A/B phase type.
In addition, Servo axis module for standard (A20B-2092-0070) does not have this restriction.
In i-series, you can use separate serial pulse coder by preparing for Pulse Module of FSSB interface.
(A02B-0236-C203, -C204).
9-6. Axis allocation of 2 controlled paths in i-series
In case that you allocate Servo axis by No.1023 in 2 controlled paths in i-series, you must not allocate the
servo axes of the another controlled path to one servo DSP.
(Bad example)
[1
st
path]
X
1
axis No.1023 = 1 → L-axis of 2 axes amplifier
• • • •
[2
nd
path]
X
2
axis No.1023 = 2 → M-axis of 2 axes amplifier
• • • •
(Good example)
[1
st
path]
X
1
axis No.1023 = 1 → L-axis of 2 axes amplifier
• • • •
[2
nd
path]
X
2
axis No.1023 = 4 → M-axis of 2 axes amplifier
• • • •