B-65292EN/03 SPECIFICATIONS 3.DIMENSIONS
- 39 -
Unit : mm
Model name T
e No.
A06B-
W
1
W
2
R
1
R
2
R
3
YZ
α50L/25000iB 1615-B120#Z318 20 30 10-15 10-15 3-5 3 or more 20 or more 40 or more
α80S/20000iB 1621-B120#Z312 20 30 10-15 10-15 3-5 3 or more 20 or more 40 or more
α80M/15000iB 1623-B170#Z011 20 30 10-15 10-15 3-5 3 or more 20 or more 40 or more
α80L/8000iB 1625-B170#Z011 20 30 10-15 10-15 3-5 3 or more 20 or more 40 or more
α100S/12500iB 1641-B120#Z011 40 50 10-15 20-25 3-5 3 or more 20 or more 60 or more
α112SS/20000iB 1661-B120#Z312 50 60 20-25 25-30 3-5 3 or more 20 or more 70 or more
α112S/15000iB 1671-B120#Z311 70 80 30-35 30-35 3-5 3 or more 30 or more 90 or more
α112M/15000iB 1673-B120#Z311 50 60 20-25 25-30 3-5 3 or more 20 or more 70 or more
α112L/15000iB 1675-B100#Z311 70 80 30-35 30-35 3-5 3 or more 30 or more 90 or more
α112LL/15000iB 1676-B100#Z311 70 80 30-35 30-35 3-5 3 or more 30 or more 90 or more
α132M/14000iB 1713-B100#Z311 80 90 35-40 35-40 3-5 3 or more 40 or more 100 or more
α132L/14000iB 1705-B140#Z311 80 90 35-40 35-40 3-5 3 or more 40 or more 100 or more
α160S/13000iB 1721-B120#Z311 50 60 30-35 30-35 3-5 3 or more 30 or more 90 or more
α160M/13000iB 1723-B120#Z311 50 60 30-35 30-35 3-5 3 or more 30 or more 90 or more
α160L/13000iB 1725-B120#Z311 50 60 30-35 30-35 3-5 3 or more 30 or more 90 or more
α160LL/13000iB 1726-B100#Z311 50 60 30-35 30-35 3-5 3 or more 30 or more 90 or more
α180M/6000iB 1743-B100#Z011 70 80 30-35 30-35 3-5 3 or more 30 or more 90 or more
α180L/6000iB 1745-B100#Z011 80 90 35-40 35-40 3-5 3 or more 40 or more 100 or more
α180LL/8000iB 1746-B100#Z011 80 90 35-40 35-40 3-5 3 or more 40 or more 100 or more
α200M/6000iB 1753-B120#Z313 80 90 35-40 35-40 3-5 3 or more 40 or more 100 or more
α200L/6000iB 1755-B120#Z316 80 90 40-45 40-45 3-5 3 or more 40 or more 110 or more
Standard type
α250M/3000iB 1773-B140#Z316 90 100 40-45 40-45 3-5 3 or more 50 or more 110 or more
α40S/70000iB 1601-B120#Z618 20 30 10-15 10-15 3-5 3 or more 20 or more 40 or more
α80S/40000iB 1631-B120#Y618 70 80 30-35 30-35 3-5 3 or more 30 or more 90 or more
α100S/20000iB 1641-B121#X617 30 40 25-30 25-30 3-5 3 or more 25 or more 50 or more
α112S/20000iB 1662-B120#Z317 70 80 30-35 30-35 3-5 3 or more 30 or more 90 or more
α112M/20000iB 1673-B100#Y617 60 70 25-30 30-35 3-5 3 or more 25 or more 80 or more
α112L/20000iB 1675-B100#Y617 50 60 30-35 30-35 3-5 3 or more 30 or more 90 or more
α112L/25000iB 1675-B140#X627 70 80 30-35 30-35 3-5 3 or more 30 or more 90 or more
α132L/25000iB 1705-B140#Y617 80 90 35-40 35-40 3-5 3 or more 40 or more 100 or more
α160M/20000iB 1723-B140#Y627 80 90 35-40 35-40 3-5 3 or more 40 or more 100 or more
α160L/20000iB 1725-B140#Y617 80 90 35-40 35-40 3-5 3 or more 40 or more 100 or more
High speed type
α160LL/20000iB 1726-B140#Y617 80 90 35-45 35-40 3-5 3 or more 40 or more 100 or more
NOTE
• R
1
is the minimum bending radius of power leads.
• Y, Z, and R
3
indicate a recommended outlet size at position X.
• If power leads or thermistor leads (THR leads) is too long, it may be cut to a usable length.
• A marking such as U, V, or W is applied at the end of each power lead. After cutting a power lead, make the power
lead capable of being determined which marking is applied on it.
• A tolerance of D
0
represents a machining dimension. The core is laminated, and a distortion of about 0.1mm may
occur in subsequent processes which include winding. However, the tolerance of D
0
is allowable for shrink fitting.
• The values in parentheses are for reference. These dimensions are managed by FANUC. It is not necessary to
machine.
• To obtain a rated output, use a cooling jacket or equivalent that shown in "3.4 COOLING JACKET". Motors are
developed with those cooling jackets. Refer to "3.4 COOLING JACKET".
• Read "II.INSTRUCTION" before designing and assembling a spindle. The motor cannot be driven normally if
handle incorrectly.
• The thermistor line of the α112SS/20000i
B extends from a tap of the power line, starting from a position 180
degrees out of phase. Provide a tap specific to the thermistor line at a position 180 degrees apart from the power
line. An alternative is to draw the thermistor line together with the power line while winding the thermistor line along
the external coil diameter.