B–64113EN/01
9. CONNECTION OF I/O Link SLAVE DEVICES
133
To the connector CA64 (IN), shown in the figure below, supply the power
necessary for this operator’s panel to operate and the power necessary for
general–purpose DI. To facilitate power branching, the powers supplied
to CA64 (IN) are output directly to CA64 (OUT). If power branching is
required, use CA64 (OUT).
01 +24V
02 0V
03
CA64 (IN)
01 +24V
02 0V
03
CA64 (OUT)
24VDC power
24VDC power
NOTE
1 Both connectors CA64 (IN) and CA64 (OUT) are same
specification. And there is not indication of (IN) and (OUT)
on the PCB.
2 Power supply for the operator’s panel must not turn off at
operation. If +24V is turned off at operation, CNC happen
to get system alarm (Communication alarm between CNC
and operator’s panel). +24V for operator’s panel must be
supplied before or same time CNC power on.
9.2.3.2
Power supply
connection