B–64113EN/01
9. CONNECTION OF I/O Link SLAVE DEVICES
162
Gray codes are output according to the table below.
Rotary switch (SA1)
% 0 1 2 4 6 8 10 15 20 30 40 50 60 70 80 90 95 100 105 110 120
Xm+0.0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0
Xm+0.1 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1
Xm+0.2 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1
Xm+0.3 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1
Xm+0.4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1
Xm+0.5 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
Rotary switch (SA2)
% 50 60 70 80 90 100 110 120
Xm+1.0 0 1 1 0 0 1 1 0
Xm+1.1 0 0 1 1 1 1 0 0
Xm+1.2 0 0 0 0 1 1 1 1
Xm+1.3 0 0 0 0 0 0 0 0
Xm+1.4 0 1 0 1 0 1 0 1
Xm+1.5 0 0 0 0 0 0 0 0
NOTE
1 Xm+0.5 and Xm+1.4 are parity bits.
2 If parity bits are used, the output timing of override signals
may differ from that of the parity bits.
9.3.5.2
Override signals