B−63085EN/02
1. DISPLAY AND OPERATION
81
The maintenance information screen has view mode and edit mode, which
are selected by pressing the [END] or [EDIT] soft key.
Initially, view mode is selected. To start editing, select edit mode by
pressing the [(OPRT)] and [EDIT] keys. When the editing is completed,
press the [END] key. Then, select [STORE] or [IGNORE]. Unless
[STORE] is selected, the edited data will be lost at next power−up.
To scroll the screen showing the recorded information, press a cursor key
or page key on the MDI panel.
The following keys are used for editing (character input) and viewing:
Operation table
Mode Key Description
View Soft keys
[EDIT]
[JUMP]
Allows editing.
Displays the beginning or the end.
Cursor key Scrolls the screen up or down.
Page key Scrolls the screen up or down in units of whole screens.
Edit Soft keys
[END]
[ALLDEL]
[I/O]
[JUMP]
Ends editing. Select whether to store the edited data.
Clears all maintenance information. (This key is enabled when the MDC bit (bit 3 of parameter 3118) is
set to 1.)
Reads or punches the maintenance information.
Moves the cursor to the beginning or end.
Cursor key Moves the cursor position up or down.
Page key Scrolls the screen up or down in units of whole screens.
Alphanumeric/spe-
cial character keys
Allows alphabetical, numeric, or special character input.
key
INSERT
Selects either insert mode or overwrite mode.
key
DELETE
Deletes a single character.
key
CAN
Deletes a single character before the cursor position.
key
INPUT
Starts a new line.
Operation of the soft keys
D Screen operation