B−63085EN/02
1. DISPLAY AND OPERATION
67
4) Waveform diagnosis data
T 6 0 D * * , * * , * * , ~ * * ,
T 6 1 D * * , * * , * * , ~ * * ,
T 6 2 D * * , * * , * * , ~ * * ,
T 6 3 D * * , * * , * * , ~ * * ,
T 6 4 D * * , * * , * * , ~ * * ,
T 6 5 D * * , * * , * * , ~ * * ,
D *..*: Waveform diagnosis data x number of axes
NOTE
1 Records are classified into header records and data
records.
2 “%” is used as an end−of−record code.
3 Each record starts with an identifier and ends with an
end−of−block code.
4 Either the ISO or EIA code system is used.
5 The output code type is specified with parameter ISO (bit 1
of No. 0100). For ISO code, parameter NCR (bit 3 of No.
0100) is used to specify whether the end−of−block code is
<LF> only, or a sequence of <LF> <CR> <CR>.
6 Parameter NFD (bit 7 of No. 01X1, where X is the channel
number) is used to specify whether a feed code is output
before and after the data.
7 No identifier word is output for a data item for which no axis
is selected.
8 The above file corresponds to a paper tape of about 200 m
in length.
(1)Once the storage is full, the oldest data is overwritten.
(2)Stored−type waveform diagnostic data is not lost, even when the
power is turned off.
(3)The waveform diagnostic function is disabled when parameter SGD
(bit 0 of No. 3112) is set to 0.
(4)Set the correct date and time using the setting screen.
1.10.6
Notes