3. INPUT AND OUTPUT OF DATA
B−63085EN/02
180
6. Press soft key [(OPRT)] and key.
7. Press [READ] key and [EXEC] key and data input is started.
Confirm the following parameters. If 1 is set, set it to 0.
(Change it in MDI mode).
#7
3201
#6
NPE
#5 #4 #3 #2 #1
RAL
#0
#1 (RAL) When programs are registered:
l 0 : All programs are registered.
1 : Only one program is registered.
#6 (NPE) When programs are registered in part program storage area, M02,M30
and M99 are:
0 : regarded as the end of program.
l 1 : not regarded as the end of porgram.
#7
3202
#6 #5 #4
NE9
#3 #2 #1 #0
NE8
#0 (NE8)
l 0 : Programs of 8000s can be edited.
1 : Programs of 8000s are protected.
#4 (NE9)
l 0 : Programs of 9000s can be edited.
1 : Programs of 9000s are protected.
For PPR, item 4 is not required.
1. Confirm that mode is EDIT mode.
2. Turn off the program protect (KEY3=1).
3. Press
PROG
key and press soft key [PRGRM] to select a part program
file.
4. Press soft key [(OPRT)],
[F SRH], and
6
[EXEC] to select
a part program file.
5. Press soft
key ,[(OPRT)] and key.
6. Press soft key [READ] and [EXEC], then data input is started.
3.2.13
Inputting Part Programs