1. DISPLAY AND OPERATION
B−63085EN/02
50
#7
SSA0408
#6 #5
SCA
#4
CME
#3
CER
#2
SNE
#1
FRE
#0
CRE
DGN
#0 (CRE): A CRC error occurred. (Warning)
#1 (FRE): A framing error occurred. (Warning)
#2 (SNE): The transmission/reception target is invalid.
#3 (CER): An error occurred during reception.
#4 (CME): No response was returned during automatic scanning.
#5 (SCA): A communication alarm occurred on the spindle amplifier side.
#7 (SSA): A system alarm occurred on the spindle amplifier side.
(These problems cause spindle alarm 749. Such problems are mainly
caused by noise, disconnection, or instantaneous power−off).
#7
0409
#6 #5 #4 #3
SPE
#2
S2E
#1
S1E
#0
SHE
DGN
Refer to this diagnosis when alarm 750 has generated.
#0 (SHE) 0 : Serial communication module is correct on CNC side.
1 : An error occurred in serial communication module on CNC side
#1 (S1E) 0: 1st spindle started normally in spindle serial control.
1 : 1st spindle did not start normally in spindle serial control.
#2 (S2E) 0 : 2nd spindle started normally in spindle serial control.
1 : 2nd spindle did not start normally in spindle serial control.
#3 (SPE) In spindle serial control serial spindle parameters
0 : Satisfy start condition of spindle unit
1 : Do not satisfy start condition of spindle unit
0410 Load meter of 1st spindle [%]
DGN
0411 Speed meter of 1st spindle [%]
DGN
0412 Load meter of 2nd spindle [%]
DGN
0413 Speed meter of 2nd spindle [%]
DGN
0414 Position error in 1st spindle synchronous control mode
DGN
0415 Position error in 2nd spindle synchronous control mode
DGN
0416 Absolute value of synchronization error between 1st and 2nd spindles
DGN
0417 Feedback information of 1st spindle position coder
DGN
0418 Position error of 1st spindle position loop mode
DGN
0419 Feedback information of 2nd spindle position coder
DGN