02 Sep.30.’03 Modification at (2)
Edit Date Design Description
Date Apr.14.2003 Desig. T.Watanabe Apprv. T.Endo
Sheet
Title
Draw
No.
3
14
FANUC Series16i/18i/21i
Cs-axis Coordinate Establishment
Function
-78845EN
Sheet
In case of failure to establish Cs axis coordinate
When Cs axis coordinate establishment is failed, P/S alarm 5346 occurs on the
path that counts up absolute coordinate (work coordinate).
And, Cs axis coordinate establishment alarm signal CSFOx<F274#4∼#7> is set
to 1 on the path connected with spindle. Then, set Cs axis coordinate
establishment request signal CSFIx<G274#4∼#7> to 0.
When you set Cs axis coordinate establishment request signal CSFIx<G274#4
∼ #7> to 0, Cs axis coordinate establishment alarm signal CSFOx<F274#4 ∼#7>
is set to 0.
Causes of Cs axis coordinate establishment failure are as follows.
- Cs axis zero point establishment state signal CSPENx is 0.
- Cs axis is under synchronous control.
- Emergency stop is applied during establishing coordinate.
- Cs axis activating current is cut during establishing coordinate (servo
alarm, servo off, etc.)
- Composite control of Cs axis is released during establishing coordinate.
- Bidirectional pitch error compensation is available to Cs axis.
- Synchronous/composite/superimposed control starts during establishing
coordinate.
Clear P/S alarm 5346
P/S alarm 5346 cannot be cleared until reference point of Cs axis is established.
Perform manual reference point return of Cs axis on the path where P/S alarm
5346 occurred. After reference point is established, P/S alarm 5346 can be
cleard with reset.
Or, P/S alarm 5346 can be cleard with reset after changing serial spindle mode
to speed control mode.