B-64223EN/01 CONNECTION 2.SPECIFICATIONS
- 17 -
2.4 SHUTDOWN OPERATION
CAUTION
Be sure to finish the OS and the applications
through the proper operation of shutdown before
turning the power off. Without the above-mentioned
operation, there is no assurance of the following
action. At worst, the hard disk drive may be
damaged and may not be able to be recognized by
the BIOS and OS.
To observe the above restrictions, a machine tool system using the
PANEL i for AUTOMOTIVE with I/O Link requires the following
measures:
(1) Use of a UPS
To circumvent the above restrictions when a power failure or
momentary power supply interruption occurs, it is advisable to
use a UPS with a power disconnection output signal.
(2) Shutdown of the system using an application software product on
the personal computer
It is advisable to shut down the system using the dedicated
software product supplied with the UPS.
2.5 CNC SCREEN DISPLAY FUNCTION (ONLY FOR THE
PANEL i FOR AUTOMOTIVE)
Expand and use CNC Screen Display Function for 10.4-inch.
Use POP-UP menu for the operation.
Be sure to install CNC Screen Display Function for the maintenance.