OPERATION
B–61404E/08
3. MANUAL OPERATION
412
If the parameter for automatic coordinate system setting (bit 7 of
parameter 010) is specified, the coordinate system is determined
automatically when a manual reference position return is made. If
α, β,
γ, and δare specified in parameters 708 to 711, the system specifies a
workpiece coordinate system such that the tip of the basic tool or a
reference position on the tool holder, after reference position return,
becomes X =
α, Y = β, Z =γ, and 4th =δ.
Once the REFERENCE POSITION RETURN COMPLETION LED
lights at the completion of reference position return, the tool does not
move unless the REFERENCE POSITION RETURN switch is turned
off.
The REFERENCE POSITION RETURN COMPLETION LED is
extinguished by either of the following operations:
– Moving from the reference position.
– Entering an emergency stop state.
For the distance (Not in the deceleration condition) to return the tool to
the reference position, refer to the manual issued by the machine tool
builder.
Explanations
D Automatic coordinate
system setting
Restrictions
D Moving the tool again
D Reference position return
completion LED
D The distance to return to
reference position