OPERATION
B–61404E/08
11. SETTING AND DISPLAYING DATA
558
Program Nos. registered are indicated.
Also, the program name can be displayed in the program table by setting
parameter No. 040#0.
SYSTEM EDITION 0466 – 25
PROGRAM NO. USED : 14 FREE : 49
MEMORY AREA USED : 275 FREE : 3820
PROGRAM LIBRARY LIST
O0010 (MACRO–GCODE.MAIN)
O2000 (MACRO GCODE.SUB1)
O0020 (TEST–PROGRAM.NO–1)
O0030 (TEST–PROGRAM.F10–MACRO)
O0200 (TEST–PROGRAM.OFFSET)
O0300
O0555 (INCH/MM CONVERT CHECK NO–1)
O1200 (MACRO–MCODE.MAIN)
> S 0 T
03:05:57 EDIT
[ PRGRM ][ CONDNS ][ ][ ][ C.A.P. ]
PROGRAM O1224 N0000
Always enter a program name between the control out and control in
codes immediately after the program number.
Up to 31 characters can be used for naming a program within the
parentheses. If 31 characters are exceeded, the exceeded characters are
not displayed.
Only program number is displayed for the program without any program
name.
(∆∆∆∆…∆)f jjjj
;
Program number
Program name (up to 31 characters)
Software series of the system is displayed.
It is used for maintenance ; user is not required this information.
Programs are displayed in the same order that they are registered in the
program library list. However, if bit 4 of parameter 040 is set to 1,
programs are displayed in the order of program number starting from the
smallest one.
Any unused areas created by background editing are counted as used
program and used memory areas. When memory is reorganized (refer to
Sec. 9.8), these unused areas are counted as free areas.
D Program library list
D Program name
D Software series
D Order in which programs
are displayed in the
program library list
D Free area