B–61404E/08
11. SETTING AND DISPLAYING DATAOPERATION
573
Procedure for enabling/displaying parameter writing
1 Select the MDI mode or enter state emergency stop.
2 Press function key
DGNOS
PARAM
.
3 Press soft key
[PARAM] to display the setting screen.
PARAMETER O1224 N0000
[ PARAM ][ DGNOS ][ ][ SV–PRM ][ ]
PART TOTAL = 17
PART REQUIRED = 50
PART COUNT = 17
RUN TIME 0H 4M CYCLE TIME 0H OM 2S
NO. PWE = = S 0 T
03:35:07
(SETTING 2)
PWE = 1 (0:DISABLE 1:ENABLE)
REV4 = 0
TAPEF = 0
(SEQUENCE STOP)
PRGNO = 0
SEQNO = 0
4 Move the cursor to
PARAMETER WRITE (PWE)using cursor keys.
5 Press
1
, then press
INPUT
key to enable parameter writing.
At this time, the CNC enters the P/S alarm state (No. 100).
6 After setting parameters, move the cursor to
PARAMETER WRITE
(PWE) and press
0
key, then press
INPUT
key.
7 Depress the
RESET
key to release the alarm condition. If alarm No. 000
has occurred, however, turn off the power supply and then turn it on,
otherwise the alarm is not released.
See Chapter 9 for setting parameters with external input/output devices
such as the Handy File.
Parameters are not effective until the power is turned off and on again after
they are set. Setting such parameters causes alarm 000. In this case, turn
off the power, then turn it on again.
Explanations
D Setting parameters with
external input/output
devices
D Parameters that require
turning off the power