B–61404E/08
4. AUTOMATIC OPERATIONOPERATION
447
2–3 Press the page key for chapter selection to display the setting
screen.
PARAMETER O0100 N0002
(SETTING 1)
_REVX = 0
REVY = 0
TVON = 0
ISO = 1 (0:EIA 1:ISO )
INCH = 0 (0:MM 1:INCH)
I/O = 0
ABS = 0 (0:INC 1:ABS)
SEQ = 0
CLOCK 97/07/07
19:32:00
NO. REVX = S 0 T
19:32:51 MDI
[ PARAM ][ DGNOS ][ ][ SV–PRM ][ ]
2–4 Move the cursor to the mirror image setting position, then set the
target axis to 1.
3 Enter an automatic operation mode (AUTO mode or MDI mode),
then press the cycle start button to start automatic operation.
For the mirror image switches, refer to the manual supplied by the
machine tool builder.
The direction of movement during manual operation, the direction of
movement from an intemidiate point to the reference position during
automatic reference position return, the direction of approach during
unidirectional positioning (G60), and the shift direction in a boring cycle
(G76, G87) cannot be reserved.
Explanations
Restrictions