B–61404E/08
11. SETTING AND DISPLAYING DATAOPERATION
565
3 The screen for displaying the workpiece origin offset values consists
of two or more pages. Display a desired page in either of the
following two ways:
Press the page up
or page down key.
Press
NO.
key and nter the workpiece coordinate system number (0:
external workpiece origin offset, 1 to 6: workpiece coordinate
systems G54 to G59, 1 to 48: workpiece coordinate systems G54 P1
to G54 P48), and then press
INPUT
key.
4 Move the cursor to the workpiece origin offset to be changed.
5 Press the address key corresponding to the desired axis.
6 Enter a desired value by pressing numeric keys, then press
INPUT
key .
The entered value is specified in the the workpiece origin offset value.
7 Repeat 4 and 6 to change other offset values.