B–63463EN/01
2. INSTALLATION
3
The peripheral units and the control unit have been designed on the
assumption that they are housed in closed cabinets.
The environmental conditions when installing internal cabinet shall
conform to the following table.
Temperature of
In operation 0_Cto 55_C
control unit
In store or transportation –20_ C to +60_C
Relative humidity 30% to 95% (no condensation)
In operation 0.5G or less
Vibration
In store or transportation 1.0G or less
Environment
Inter of units: Each unit should be placed in a cabinet
to keep it from pollutants (such as dust, coolant, organic
solvents, acid, corrosive gas, and salt).
Heat sink of outer of cabinet: The heat sinks should be
protected from direct exposure to coolant, lubricant, and
metal chips.
Radiation
(ionizing or nonion-
izing)
If a unit is to be used in an environment where it is likely
to be exposed to radiations (such as microwave,
ultraviolet rays, laser beams, and X–rays), a shielding
provision should be available for it.
Height above sea
In operation Up to 1,000 m
level
In store or transportation Up to 12,000 m
Sections 2.3 and 2.4 describes the installation and design conditions of
a cabinet satisfying these conditions.
2.1
ENVIRONMENTAL