7. CONNECTION TO PERIPHERALS
B–63463EN/01
58
When a separate pulse coder or linear scale is used, a separate detector
interface unit is required. The separate detector interface unit should be
connected to the Digital Servo Adapter control unit through an optical
fiber cable, as one of the units on the servo interface (FSSB). See Figures
in Sec. 7.3. The separate detector interface connected in the final stage
of the FSSB line, it can also be connected, at the nearest location, to the
Digital Servo Adapter control unit. Or, it can be installed between two
servo amplifier modules.
Usually, the separate detectors corresponding to the servo motors for the
first to eighth axes are connected to JF101 to JF108 of the separate
detector interface. If required, the controlled axis numbers corresponding
to JF101 to JF108 may be changed. For example, in the figure above, if
separate detectors are used for the second, fourth, sixth, and eighth
controlled axes only, the second, fourth, sixth, and eighth axes can be
made to correspond to JF101 to JF104 of the basic unit, eliminating the
need for an additional unit. The power that the unit can supply to separate
detectors is 0.35 A (5V) per detector.
Item Specifications
Power supply Stabilized power supply: 24 VDC ±10%
Current: 0.9 A (for basic only), 1.5 A (for additional)
Ordering
specification
A02B–0230–C203 (basic)
A02B–0236–C204 (additional)
Installation The unit can be secured with screws or DIN rail.
7.4
SEPARATE
DETECTOR
INTERFACE UNIT
7.4.1
General