6. CONNECTION USING THE HSSB
39
(1)Rotary switch on the personal computer
Using the rotary switch on the personal computer, set the base address
of the I/O space used by this HSSB board.
A20B–8001–0583
The I/O base address of
the interface board will be:
LMN0H*
The factory settings are as follows:
For A20B–8001–0581 and –0583, the
settings for channel A (COP7A) are:
L,M,N
=0,2,8
For A20B–8001–0580 and –0582, the
settings for channel A (COP7A) are:
L,M,N
=0,2,8
The settings for channel B (COP7B)
are:
L,M,N
=0,2,9
Interface board
(As viewed from the top of the board)
LMN
Channel A
Channel B
A20B–8001–0582
Channel A
* If the base address is LMN 0h,
* addresses LMN 0h to LMN Fh are used.
(2)Rotary switch on the Digital Servo Adapter
The rotary switch on the HSSB board on the Digital Servo Adapter is
used to select the following operating modes.
Rotary switch on the HSSB
board on the Digital Servo
Adapter
Description
SW1
0
SW=0
Setting for maintenance.
The startup menu is displayed, enabling Digital
Servo Adapter boot and IPL operations from
the customer control unit (provided that the
customer control unit support these functions).
SW1
1
SW=1
Normal setting.
The startup menu is not displayed.
It is not possible to perform Digital Servo
Adapter boot and IPL operations from the
customer control unit.
SW1
2
SW=2
The Digital Servo Adapter is started
independently of the customer control unit.
The startup menu is not displayed. It is not
possible to perform Digital Servo Adapter boot
and IPL operations from the customer control
unit.
6.4
SWITCHES FOR
SETTING UP THE
INTERFACE BOARDS
FOR THE ISA BUS