18. MANUAL OPERATION
B–63172EN/01
NC FUNCTION
106
D Jogging
Each axis can be moved in the + or – direction for the time the button
is pressed. Feed rate is the parameter set speed with override of:
0 – 655.34%, 0.01% step.
The parameter set speed can be set to each axis.
D Manual rapid feed
Each axis can be fed in a rapid feed to the + or – direction for the time
the button is pressed.
Rapid traverse override is also possible.
Specified move amount can be positioned to the + or – direction with the
button.
Move amount of:
(least command increment) x (magnification)
can be specified. The feed rate is that of manual feed.
The possible magnifications to be specified are as follows.
×1, ×10, ×100, ×1000.
By rotating the manual pulse generator, the axis can be moved for the
equivalent distance. Manual handle feed is controlled 1 axis at a time.
The manual pulse generator generates 100 pulses per rotation. Move
amount per pulse can be specified from the following magnifications:
×1, ×10, ×M, ×N.
N is parameter set values of 0 – 1000. M is parameter set values of 1–127.
Move distance is :
(Least command increment) x (magnification)
Increment system Metric input Inch input
IS–B 0.001, 0.01, M/1000,
N/1000 mm
0.0001, 0.001, M/10000,
N/10000 inch
IS–C 0.0001, 0.001, M/10000,
N/10000 mm
0.00001, 0.0001, M/100000,
N/100000 inch
18.1
MANUAL FEED
18.2
INCREMENTAL FEED
18.3
MANUAL HANDLE
FEED (1ST)