B–63325EN/03
2. 15i SERIES HARDWARE
131
With the rotary switch SW1 on the board and the setting pin SW5 on the
intelligent terminal or Panel i, the starting sequence at power–up can be
changed.
Rotary
switch SW1
setting
Setting pin
SW5
setting
Description
0 Open Setting for maintenance purposes
The start menu is displayed, and booting or IPL can be
performed from the intelligent terminal or Panel i.
1 Open Setting for normal operation
The start menu is not displayed.
Booting or IPL cannot be performed from the intelligent
terminal or Panel i.
2 Shorted The CNC and the intelligent terminal or Panel i will be
started independently of each other without handshak-
ing.
– CNC
– Even if the intelligent terminal or Panel i is not con-
nected or turned on, it is possible to start the CNC
only and operate it. (Its operation requires a dis-
play dedicated to the CNC, an MDI, an operator
panel, and others.)
– Even if the intelligent terminal or Panel i is con-
nected and turned on, the start menu is not dis-
played.
– Intelligent terminal or Panel i
– Even if the CNC is not connected or turned on, it is
possible to start the intelligent terminal or Panel i
only and operate it.
– The temperature control function of the intelligent
terminal or Panel i does not operate. Make sure
that the intelligent terminal or Panel i is in the rec-
ommended operating temperature range before
using it.
– Even if the CNC is connected and turned on, the
start menu is not displayed. It is not possible to
perform boot and IPL operations from the intelligent
terminal or Panel i.
During normal operation, this setting is disabled. Use
this setting during maintenance only.
NOTE
1 For the location of the setting pin SW5 of intelligent terminal,
see Section 2.15.2. For the location of the setting pin SW5
of Panel i, see the Appendix C.
2 Avoid turning on or off the CNC control unit while the
intelligent terminal is alive.
3 The PCI bus version of the intelligent terminal has been
renamed to the ”FAUNC Panel i.”
D Setting adjustments
Rotary switch SW1
(for connecting an
intelligent terminal or
Panel i)