B–63325EN/03
7.TROUBLESHOOTING
373
(1)If automatic operation stops, determine the cause by applying the
procedure explained below.
(2)Check the automatic operation start (cycle start) lamp on the machine
operator’s panel.
(3)Check the CNC diagnosis function.
(1)If the automatic operation start signal (STL) is turned off by a reset,
diagnosis No. 1010 outputs data on the CNC as follows:
#7
1010
#6 #5 #4 #3
RST
#2
ERS
#1
RRW
#0
ESP
If each item is set to 1, it has the following meaning:
a. ESP Emergency stop state
b. RRW The reset & rewind signal is on.
c. ERS The external reset signal is on.
d. RST The reset key is pressed.
Note) The following provides detailed information about items a to d,
above. Check the status of the relevant signal by using the PMC
(PMCDGN) diagnosis function.
a. The emergency stop signal has been input.
#7
X0006
#6 #5 #4
*ESP
#3 #2 #1 #0
#7
G0000
#6 #5 #4
*ESP
#3 #2 #1 #0
If *ESP is 0, the emergency stop signal is currently being input.
b. The reset & rewind signal has been input.
#7
G0000
#6
RRW
#5 #4 #3 #2 #1 #0
If RRW is 1, the reset & rewind signal is currently being input.
Note) This signal is normally used as the confirmation signal sent
from the PMC when M30 is specified at, for example, the
termination of a program. Therefore, after program
termination, the reset & rewind signal is input.
7.5
AUTOMATIC
OPERATION START
SIGNAL TURNED
OFF
[Point]
[Cause and action]