#7
DTBLDSPK900
#6 #5 #4
MEMINP
#3 #2
AUTORUN
#1
PRGRAM
#0
LADMASK
#7 DTBLDSP 0 : Displays the PMC parameter data table control screen.
1 : Does not display the PMC parameter data table control screen.
#4 MEMINP 0 : Disables data entry on the signal status screen.
1 : Enables data entry on the signal status screen.
: The signal status screen is displayed by the online function of FAPT
LADDER–II or ladder editing package.
#2 AUTORUN 0 : The sequence program is executed automatically after the power is
switched on.
1 : The sequence program execution soft key is used to start the sequence
program.
#1 PRGRAM 0 : Disables the built–in debug function.
1 : Enables the built–in debug function.
#0 LADMASK 0 : Activates the ladder dynamic display.
1 : Deactivates the ladder dynamic display.